Instructions for human transforming growth factor alpha (TGF-α) Elisa kit

Human Transforming Growth Factor α (TGF-α) Elisa Kit Instructions This kit is for research use only.
Detection range: 96T
100 ng / L -3200 ng / L
purpose of usage:
This kit is used to determine the content of transforming growth factor α (TGF-α) in human serum, plasma and related liquid samples.
Experimental principle of human transforming growth factor α (TGF-α) Elisa kit instructions This kit uses the double antibody sandwich method to determine the level of human transforming growth factor α (TGF-α) in the specimen. Microporous plates were coated with purified human transforming growth factor alpha (TGF-α) antibody to make solid-phase antibodies. Transforming growth factor alpha (TGF-α) was added to the microwells coated with mAb in turn, and then labeled with HRP The transforming growth factor α (TGF-α) antibody binds to form an antibody-antigen
-Enzyme-labeled antibody complex, after thorough washing, add substrate TMB to develop color. TMB turns into blue under the catalysis of HRP enzyme,
And converted into the final yellow under the action of acid. The color depth is positively correlated with the transforming growth factor α (TGF-α) in the sample. The absorbance (OD value) was measured with a microplate reader at a wavelength of 450 nm, and the concentration of human transforming growth factor α (TGF-α) in the sample was calculated by a standard curve.
Kit composition
1 30 times concentrated washing solution 20ml × 1 bottle 7 stop solution 6ml × 1 bottle
2 Enzyme label reagent 6ml × 1 bottle 8 standard (6400 ng / L) 0.5ml × 1 bottle
3 Enzyme label coated plate 12 wells × 8 strips 9 standard dilutions 1.5ml × 1 bottle
4 Sample diluent 6ml × 1 bottle 10 instructions 1 copy
5 Developer A solution 6ml × 1 bottle 11 2 sealing film
6 Developer B solution 6ml × 1 / bottle 12 sealed bag 1 specimen requirement
1. Specimens are extracted as soon as possible after collection, and extraction is performed according to relevant literature, and experiments should be conducted as soon as possible after extraction. If the test cannot be performed immediately, the specimen can be stored at -20 ℃, but repeated freezing and thawing should be avoided
2. Samples containing NaN3 cannot be detected because NaN3 inhibits horseradish peroxidase (HRP) activity.
Steps
1. Dilution of standard products: This kit provides one original standard product. The user can perform dilution in a small test tube according to the following chart.
3200 ng / L No. 5 standard 150μl original standard added 150μl standard dilution
1600 ng / L No. 4 standard 150μl No. 5 standard added 150μl standard dilution
800 ng / L No. 3 standard 150μl No. 4 standard added 150μl standard dilution
400 ng / L No. 2 standard 150μl No. 3 standard added 150μl standard diluent
200 ng / L No. 1 standard 150μl No. 2 standard added 150μl standard dilution
2. Add sample: set up blank wells separately (the blank control wells do not add samples and enzyme label reagents, the rest of the steps are the same), standard wells,
Sample hole to be tested. Add 50μl of the standard on the enzyme-coated plate accurately, and add 40μl of sample diluent to the sample well.
Then add 10μl of the sample to be tested (the final dilution of the sample is 5 times). Add the sample and add the sample to the bottom of the well of the microplate, try not to touch the wall of the well, shake gently to mix.
3. Incubation: seal the plate with the sealing film and incubate at 37 ° C for 30 minutes.
4. Mixing solution: Dilute 30 times concentrated washing liquid with distilled water 30 times and reserve
5. Washing: Carefully peel off the sealing film, discard the liquid, spin dry, fill each well with the washing liquid, let it stand for 30 seconds, then discard, repeat 5 times and pat dry.
6. Add enzyme: add 50μl of enzyme label reagent to each well, except blank well.
7. Incubation: The operation is the same as 3.
8. Washing: The operation is the same as 5.
9. Color development: add 50μl of developer A to each well, and then add 50μl of developer B, mix gently, and develop color at 37 ℃ in the dark
15 minutes.
10. Termination: Add 50μl of stop solution to each well to stop the reaction (at this time the blue will turn to yellow).
11. Determination: Measure the absorbance (OD value) of each well in sequence with the blank air conditioner at zero and 450nm wavelength. The measurement should be carried out within 15 minutes after adding the stop solution.
Summary of operating procedures:
The calculation takes the concentration of the standard as the abscissa and the OD value as the ordinate, and draws a standard curve on the coordinate paper.
The corresponding concentration of OD value is found from the standard curve; then multiplied by the dilution factor; or the linear regression equation of the standard curve is calculated from the concentration of the standard and the OD value, and the OD value of the sample is substituted into the equation to calculate the sample concentration With a dilution factor,
This is the actual concentration of the sample.
Precautions
1. The kit should be taken out of the refrigerated environment and equilibrated at room temperature for 15-30 minutes before use. If the enzyme-coated plate is unsealed after opening, the strip should be stored in a sealed bag.
2. Crystals may be precipitated in the concentrated washing liquid, which can be heated and dissolved in a water bath during dilution, and the results will not be affected during washing.
3. The sampler should be used at each step of sample addition, and the accuracy should be regularly checked to avoid test errors. It is best to control the sampling time within 5 minutes. If there are many specimens, it is recommended to use a volley gun to add samples.
4. Please make a standard curve at the same time of each measurement, it is best to make a double hole. If the content of the substance to be tested in the specimen is too high (the OD value of the sample is greater than the OD value of the first well of the standard well), please dilute it with a certain multiple (n times) of the sample diluent and then determine it. Please multiply the total dilution for the calculation Multiple (× n × 5).
5. The sealing film is limited to one-time use to avoid cross-contamination.
6. Please keep the substrate away from light.
7. Strictly follow the instructions, and the test results must be determined by the microplate reader.
8. All samples, washing liquids and various wastes should be treated as infectious agents.
9. The components of different batches of this reagent shall not be mixed.
Storage conditions and validity period
1. Kit storage :; 2-8 ℃.
2. Validity: 6 months Human Transforming Growth Factor α (TGF-α) Elisa kit instructions

A Makeup Mirror is a classification of mirrors, mainly referring to small mirrors that are exquisitely designed and easy to carry.

Maintenance:

1. After using the makeup mirror, wipe the fingerprints and stains with a soft cloth to keep the product fresh.
2. When the makeup mirror is idle, it can be placed in a velvet bag to prevent air from oxidizing.
3. should try to avoid scraping with hard objects, so as not to cause mirror damage.

Makeup Mirror Magnifying

Hand Mirror For Sale

Makeup Mirror

Beauty Mirror,Makeup Mirror,Makeup Vanity Mirror,Vanity Mirror,Cosmetic Face Mirrors,Cosmetic Mirror,Magnifying Mirror

YANGJIANG HUIHUI BEAUTY TOOLS CO.,LTD , https://www.yjhuihuibeauty.com

Posted on