Human oxytocin (OT) elisa kit instruction manual

Human Oxytocin (OT) elisa Kit Instruction Manual Elisa kit Specifications: 48-well configuration / 96-well configuration Standard dilution: 1.5ml × 1 bottle of enzyme standard reagent: 3 ml × 1 bottle (48) / 6 ml × 1 bottle (96) [Human Oxytocin (OT) elisa kit] This reagent is only for research use calculation: the concentration of the standard is the abscissa, the OD is the ordinate, and the standard curve is drawn on the coordinate paper, according to the OD of the sample. The value is determined from the standard curve by the corresponding concentration; multiplied by the dilution factor; or the linear regression equation of the standard curve is calculated from the concentration of the standard and the OD value, and the OD value of the sample is substituted into the equation to calculate the sample concentration, and then multiplied by The dilution factor is the actual concentration of the sample. Kit composition: sealing film: 2 pieces (48) / 2 pieces (96) Instructions: 1 part sealed bag: 1 standard: 2700ng / L 0.5ml × 1 bottle 0.5ml × 1 bottle 2-8 ° C preservation enzyme Standard package: 1×48 1×96 2-8°C Preservation of sample dilution: 3ml×1 bottle 6 ml×1 bottle 2-8°C Preservation of developer A: 3ml×1 bottle 6 ml×1 bottle 2 Store chromogen B solution at -8 °C: 3ml × 1 bottle 6 ml × 1 bottle 2-8 ° C Preservation solution: 3ml × 1 bottle 6ml × 1 bottle 2-8 ° C Preservation concentrated washing solution: (20ml × 20 times) ×1 bottle (20ml×30 times)×1 bottle 2-8°C preservation experiment principle: This kit uses double antibody sandwich method to determine human oxytocin (OT) level in specimens. The microporous plate was coated with purified human oxytocin (OT) antibody to prepare a solid phase antibody, and oxytocin (OT) was sequentially added to the microcapsule of the coated monoclonal antibody, followed by HRP-labeled oxytocin (OT). The antibody binds to form an antibody-antigen-enzyme-labeled antibody complex, which is thoroughly washed and then added to the substrate TMB for color development. TMB is converted to blue under the catalysis of HRP enzyme and converted to the final yellow color by the action of an acid. The color depth is positively correlated with oxytocin (OT) in the sample. The absorbance (OD value) was measured at 450 nm using a microplate reader, and the human oxytocin (OT) concentration in the sample was calculated from a standard curve. Purpose: This kit is used to determine the levels of oxytocin (OT) in human serum, plasma and related fluid samples. Service commitment: ? Delivery period: payment to delivery. Free technical advice and guidance during working hours? Please call to provide customers with sample testing services to maximize the effectiveness of the experimental results (free proxy). Storage conditions and expiration date: kit storage: 2-8 ° C | Validity: 6 months [human oxytocin (OT) elisa kit] sample processing and requirements: 1. Serum: room temperature blood naturally coagulates for 10-20 minutes, centrifuge 20 About a minute (2000-3000 rev / min). The supernatant is carefully collected, and if precipitation occurs during storage, it should be centrifuged again. 2. Plasma: EDTA or sodium citrate should be selected as an anticoagulant according to the requirements of the specimen. After mixing for 10-20 minutes, centrifuge for about 20 minutes (2000-3000 rpm). The supernatant is carefully collected, and if a precipitate forms during storage, it should be centrifuged again. 3. Urine: Collect with a sterile tube and centrifuge for about 20 minutes (2000-3000 rpm). The supernatant is carefully collected, and if a precipitate forms during storage, it should be centrifuged again. The chest and ascites and cerebrospinal fluid are referred to. 4. Cell culture supernatant: When detecting secreted components, collect them in a sterile tube. Centrifuge for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. When the components in the cells were detected, the cell suspension was diluted with PBS (pH 7.2-7.4), and the cell concentration reached about 1 million/ml. By repeated freezing and thawing, the cells are destroyed and the intracellular components are released. Centrifuge for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. If a precipitate forms during storage, it should be centrifuged again. 5. Tissue specimen: After cutting the specimen, weigh the weight. Add a certain amount of PBS, pH 7.4. It was quickly frozen and stored in liquid nitrogen for use. The specimen still maintains a temperature of 2-8 ° C after melting. A certain amount of PBS (pH 7.4) was added, and the specimen was homogenized by hand or homogenizer. Centrifuge for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. One part of the package is to be tested, and the rest is frozen for use. 6. The specimens should be extracted as soon as possible after collection, and the extraction should be carried out according to the relevant literature. The experiment should be carried out as soon as possible after extraction. If the test cannot be performed immediately, the specimen can be stored at -20 °C, but repeated freezing and thawing should be avoided. 7. Samples containing NaN3 cannot be detected because NaN3 inhibits horseradish peroxidase (HRP) activity. Dilution and loading of standard steps: 10 wells of standard wells on the enzyme label coating plate, 100 μl of standard in the first and second wells, and then standard in the first and second wells 50 μl of the dilution solution, and mix; then, 100 μl of each of the first hole and the second hole are respectively added to the third hole and the fourth hole, and then 50 μl of the standard dilution solution is added to the third and fourth holes, respectively, and mixed; Then, 50 μl of each of the third hole and the fourth hole are discarded, and 50 μl of each is added to the fifth and sixth holes, respectively, and 50 ul of the standard dilution is added to the fifth and sixth holes, respectively, and mixed; After mixing, 50 μl from each of the fifth and sixth wells was added to the seventh and eighth wells respectively, and then 50 μl of the standard dilution was added to the seventh and eighth wells, and the mixture was mixed from the seventh and the seventh. 50 μl of each of the eight wells was added to the ninth and tenth holes, and 50 μl of the standard dilution was added to the ninth and tenth holes, respectively, and 50 μl of each of the ninth and tenth holes was discarded. (The amount of each well was 50 μl after dilution, and the concentrations were 1800 ng/L, 1200 ng/L, 600 ng/L, 300 ng/L, 150 ng/L, respectively). Adding samples: Set blank holes separately (the blank control wells are not added with the sample and the enzyme standard reagent, and the other steps are the same), and the sample holes to be tested. Add 40 μl of the sample dilution to the sample well to be tested on the enzyme-labeled plate, and then add 10 μl of the sample to be tested (the final dilution of the sample is 5 times). Add the sample to the bottom of the well of the microplate, try not to touch the wall of the well, and shake gently to mix. Incubation: The plate was sealed with a sealing film and incubated at 37 ° C for 30 minutes. Solution: 30 (48 times of 20T) concentrated washing solution was diluted with distilled water 30 (20 times of 48T) and used. Washing: Carefully remove the sealing film, discard the liquid, dry it, fill each well with the washing solution, let stand for 30 seconds, then discard it, repeat 5 times, and pat dry. Add enzyme: 50 μl of enzyme labeling reagent was added to each well, except for blank wells. Incubation: The operation is the same as 3. Washing: The operation is the same as 5. Color development: Add 50 μl of chromogenic reagent to each well, then add 50 μl of chromogenic reagent, gently shake and mix, and smear for 15 minutes at 37 ° C. Stop: 50 μl of stop solution per well, stop the reaction (blue at this time) Turn yellow.) Measurement: The absorbance (OD value) of each well was measured in sequence with a blank air conditioner of zero and a wavelength of 450 nm. The measurement should be carried out within 15 minutes after the addition of the stop solution. [Human Oxytocin (OT) elisa kit] Note: The kit should be taken out from the refrigerated environment and should be used at room temperature for 15-30 minutes before use. If the enzyme label is unsealed after the plate is unsealed, the slats should be loaded. Store in a sealed bag. Concentrated washing liquid may crystallize out. When diluted, it can be heated and dissolved in a water bath. The washing does not affect the result. The sampler should be used for each step and the accuracy should be corrected frequently to avoid test errors. It is best to control the loading time within 5 minutes. If the number of specimens is large, it is recommended to use a gun. Please make a standard curve at the same time of each measurement, it is best to make a double hole. If the content of the substance to be tested in the specimen is too high (the OD value of the sample is larger than the OD value of the first hole of the standard well), please first dilute the sample dilution with a certain multiple (n times) and then measure it. When calculating, multiply the total dilution by the total dilution. Multiple (×n×5). The sealing film is intended for single use only to avoid cross-contamination. Keep the substrate away from light. Strictly follow the instructions of the manual, the test results must be based on the reading of the microplate reader. All samples, washing liquid and various wastes should be treated as infectious materials. The different batch components of this reagent must not be mixed. 10. In the case of an English manual, the English manual shall prevail. Kit performance: 1. Sample linear regression and expected concentration correlation coefficient R value of 0.95 or more. 2. Within and within the batch should be less than 9% and 11% detection range: 0.2IU / L - 6IU / L Provide a variety of species, a variety of ELISA scientific research test kits. Buy any of the company's Elisa kits, can provide generation of testing services, spot direct sales, quality is guaranteed, the model can be shipped the same day, free express delivery, please contact our company customer service, 60496050

       This machine unit is manufactured and designed by modern advanced technology, for many years manufacturing Cast Film machinery and using practical basis, by means of abundant experience in the film field. It`s mainly apply for producing single-layer or three layers / multiple layer co-extrusion CPP, CPP Cast Film Line,CPE, EVA and high-Barrier food packaging film containing EVOH and PE, it is widely use for food, packaging, construction, agriculture etc industries. 

Co-Extrusion CPP Casting Film Machine

CPP Casting Film Machine,CPP Plastic Cast Film Machine,CPP Casting Film Extrusion Machine,CPP Cast Film Line

Sunny Machinery Factory , https://www.stsunnymachine.com

Posted on